Move an object from one location to another within the Management Platform.
Move an object from one location to another within the Management Platform
SYNTAX
DESCRIPTION
Moves an object from the Management Platform. You can specify an ObjectType or ObjectName redirecting it into a DestinationFolderName or DestinationFolderId.
EXAMPLES
1. Move a site from a FOlder called 'Testing' to a folder called 'New'
2. Move a device from a Folder called 'Testing Powershell' to a folder called 'Test2'
PARAMETERS
-ObjectType
The type of object being renamed ('Folder','Device','Profile','Site','SoftwarePackage','Role','User','Broker','Notification','License')
Type: | String |
Required: | Yes |
Accept Pipeline Input: | No |
Accepted values: | Folder, Device, Profile, Site, SoftwarePackage, Role, User, Broker, Notification, License |
-DestinationFolderName
The fully qualified name of the destination folder
Type: | String |
Required: | No |
Accept Pipeline Input: | No |
-DestinationFolderId
The GUID of the destination folder (not required if destinationFolderName is supplied)
Type: | String (GUID) |
Required: | No |
Accept Pipeline Input: | No |
-Object
A comma-delimited list of object GUID's to move (not required if objects are supplied)
Type: | ThinScale.Management.DataObjects.IObject |
Required: | Yes |
Accept Pipeline Input: | Yes |
-ObjectName
A comma-delimited list of fully qualified object names to move
Type: | String |
Required: | No |
Accept Pipeline Input: | No |
-ObjectId
A comma-delimited list of object GUID's to move (not required if objects are supplied)
Type: | String (GUID) |
Required: | No |
Accept Pipeline Input: | No |
-Interface
The interface ID returned by a previously successful call to Connect-TSTMGMTServer. This parameter is only required if you are connected to 2 or more Management Platform instances at the same time. If this parameter is not specified the connection to the last successful call to Connect-TSTMgmtServer will be used.
Type: | String (GUID) |
Required: | No |
Accept Pipeline Input: | No |
-Timeout
The time allowed in milliseconds for the call to complete before it is deemed to have timed out and is aborted
Type: | Int32 |
Required: | No |
Accept Pipeline Input: | No |
-Force
If multiple objects are found with the same name, the first retrieved will be used otherwise the call will fail
Type: | SwitchParameter |
Required: | No |
Accept Pipeline Input: | No |
INPUTS
ThinScale.Management.DataObjects.IObject
OUTPUTS
System.Object